A low bioimpedance phase angle predicts a higher mortality and lower nutritional status in chronic dialysis patients
This article has been downloaded from IOPscience. Please scroll down to see the full text article.
2010 J. Phys.: Conf. Ser. 224 012104
(http://iopscience.iop.org/1742-6596/224/1/012104)
View the table of contents for this issue, or go to the journal homepage for more
Download details:
IP Address: 24.180.86.119
The article was downloaded on 21/05/2010 at 13:53
Please note that terms and conditions apply.
Francis Dumler MD
Division of Nephrology, William Beaumont Hospital, Royal Oak, MI 48073, USA
fdumler@beaumont.edu
Abstract Bioelectrical impedance analysis is an established technique for body composition
analysis. The phase angle parameter, an index of body cell mass, tissue hydration, and
membrane integrity, makes it suitable for assessing nutritional status and survivability. We
evaluated the significance of a low phase angle value on nutritional status and mortality in 285
chronic dialysis patients during a longitudinal prospective observational study. Patients in the
lower phase angle tertile had decreased body weight, body mass index, fat free mass, body cell
mass, and lower serum albumin concentrations than those in the higher tertile (P<001). In
addition, mortality rates were significantly lower (P=0.05) in the highest tertile patients. In
conclusion, the phase angle is a useful method for identifying dialysis patients at high risk for
malnutrition and increased mortality.
1. Introduction
The evaluation of nutritional status is of significance importance in the care of dialysis patients. Even
though improvements in management of cardiovascular diseases, infections, and dialysis therapies
have been significant, mortality in the chronic kidney disease population continues unabated.
Malnutrition, whether alone or in association with a micro inflammatory state, affects 30-70% of
patients and is clearly identified as a significant risk factor for survival [1-4]. Anthropometric and
biochemical parameters have been traditionally used for nutritional assessment in clinical practice.
More recently, bioelectrical impedance analysis (BIA) has established itself as a technique for
evaluating body composition and nutritional status [5]. In addition, the phase angle parameter
(arctangence of the reactance to resistance ratio) provides an index of tissue hydration, cell membrane
integrity, and cell mass [6]. The objective of this study was to determine if a low phase angle is
associated with a decreased nutritional status and/or higher mortality in chronic dialysis patients.
2. Patients and methods
This is a prospective longitudinal observational study of 285 chronic maintenance dialysis patients.
Bioelectrical impedance analysis was done with a single 50 kHz frequency analyzer using tetrapolar
electrodes attached to the ipsilateral wrist and ankle 15 minutes post hemodialysis or before a fill in
peritoneal dialysis patients. Even at this low frequency the influence of stray capacitance cannot be
neglected. For this reason, a parallel model (CyprusTM 1.2 RJL Systems, MI, USA) was used for body
composition calculations [7]. Briefly, this model assumes a parallel circuit composed of a resistor Rp
positioned in parallel with a capacitor Cp, where both electrical processes occur independently, thus
allowing evaluation of the bulk electrical properties of tissues.
Parameters: body weight, body mass index and serum chemistries (blood urea nitrogen, creatinine,
and albumin) were evaluated monthly. Bioimpedance parameters (phase angle, and derived body cell
mass, fat free mass and fat mass) were measured biannually. Fat free mass was calculated as:
Males: -10.68 + 0.65 x (Height2/Resistance) + 0.26 x Weight + 0.02 x Resistance
Females: -9.35 + 0.69 x (Height2/Resistance) + 0.17 x Weight + 0.02 x Resistance
Statistical analysis: mean values for the entire observation period were obtained. Patients were
divided into tertiles according to phase angle values. Comparisons between tertile groups were made
by analysis of variance and post hoc testing.
3. Results
Demographic characteristics were as follow: age: 62 ± 14 years; weight: 75 ± 18; body mass index:
26.3 5.2 kg/m2, 59% male, and 37% black. The prevalence of diabetes was 43%. Dialysis modality
was 72% hemodialysis and 28% peritoneal dialysis. The median observation time was 18 months.
Body weight and body mass index values were significantly different in the phase angle tertile
groups (P < 0.001); with the lesser values corresponding to the lower tertile in both hemodialysis and
peritoneal dialysis patients (table 1, table 2). No differences were noted in mean phase angle values
between hemodialysis and peritoneal dialysis patients. As expected, peritoneal dialysis patients had a
higher body weight than their hemodialysis counterparts. Biochemical profiles were also significantly
different in the tertile groups (P < 0.001) with the smallest values in the low tertile group in both
hemodialysis and peritoneal dialysis patients (table 1, table 2). No differences were noted in mean
phase angle values between hemodialysis and peritoneal dialysis patients. As expected, peritoneal
dialysis patients had lower serum albumin concentrations than their hemodialysis counterparts.
In hemodialysis and peritoneal dialysis patients significant differences between all tertile groups
were noted for body cell and fat free mass (P < 0.01). Fat mass was decreased only in the lowest
tertile hemodialysis group (table 1). Further analyses were done combining hemodialysis and
peritoneal dialysis patients. All nutritional parameters were significantly lower (P < 0.05) in the low
tertile group when compared to the other groups (table 3). Mortality rates, calculated per 1000 patient
months, was significantly decreased (P< 0.05) in the upper tertile group (table 3).
4. Discussion
The use of bioelectrical impedance analysis is becoming more widespread in the renal community due
to ease of use and a low coefficient of variation for the direct measurements (±1%). In addition,
several population reference values have been reported recently [6-10]. This facilitates comparisons
between patients and a more specific general (healthy) population. Its reliability and sensitivity also
makes it very useful for longitudinal monitoring of chronic kidney disease patients.
This study demonstrates that bioelectrical impedance analysis, in particular the phase angle, is a useful
clinical tool for detecting malnutrition in dialysis patients. The phase angle reflects the relative
contribution of body fluid (resistance) and cellular membrane integrity (capacitance). Malnutrition
reduces cellular membrane mass and integrity and promotes shifts in fluid balance. As a consequence
of these changes the phase angle decreases. Conversely, a higher phase angle implies larger body cell
mass and preserved membrane integrity.
Patients with smaller phase angle values, defined by < 4.10 (lowest tertile group), had lower body
weight and body mass index than their counterparts. In addition, serum creatinine concentration was
concomitantly decreased, implying less dietary protein intake and lower muscle mass. Finally, body
cell mass and fat free mass were also decreased in patients with a low phase angle.
The finding of a lower mortality rate among patients in the higher phase angle tertile is expected, as
this group had a better nutritional status. One large multicenter study has shown a direct relationship
between phase angle and survival in hemodialysis patients [1]. Another study in forty eight peritoneal
dialysis patients found a close relationship between phase angle and mortality [11]. Our study has the
advantage of including a relatively large patient population treated at a single facility by the same
health care team.
Uremic malnutrition and chronic inflammation are highly prevalent in maintenance dialysis
patients [12]. A low phase angle may be a consequence of both processes. Of interest in this regard is
the observation that phase angle is a predictor of all-cause mortality after adjusting for serum C-
reactive protein concentrations [13]. The use of ultrapure dialysis fluid and polyamide dialyzers for
on-line predilution hemodiafiltration over a six month period has also been linked to a significant
decrease in inflammatory markers and improved nutritional parameters [14]. In that particular study a
dramatic fall in C-reactive protein was time related to a significant increase in phase angle. Of
interest, several studies have shown an inverse relationship between phase angle and survival rates in a
variety of disease processes including HIV, post-operative complications, cancer, and cirrhosis [6, 15].
In conclusion, these results suggest that bioelectrical impedance analysis and phase angle
measurements are a useful tool for identifying dialysis patients at high risk for malnutrition and/or
increased mortality.
Refrences



